Lenovo Flex System x220 Installation And Service Manual page 378

Compute node
Hide thumbs Also See for Flex System x220:
Table of Contents

Advertisement

1. Check the Support Portal for service bulletins and RETAIN tips related to your drive.
2. Check the Support Portal for firmware updates related to your drive.
3. Replace the drive.
4. Check for any other RAID-related errors.
• 806f010d-0406ffff : The Drive Drive 6 has been disabled due to a detected fault.
The hard disk drive controller has detected a fault in hard disk drive 6. Hard disk drive 6 is now defunct.
May also be shown as 806f010d0406ffff or 0x806f010d0406ffff
Severity
Error
Serviceable
Yes
Automatically notify support
Yes
Alert Category
Critical - Hard Disk drive
SNMP Trap ID
5
CIM Information
Prefix: PLAT ID: 0164
User Response
Complete the following steps until the problem is solved:
1. Check the Support Portal for service bulletins and RETAIN tips related to your drive.
2. Check the Support Portal for firmware updates related to your drive.
3. Replace the drive.
4. Check for any other RAID-related errors.
• 806f010d-0407ffff : The Drive Drive 7 has been disabled due to a detected fault.
The hard disk drive controller has detected a fault in hard disk drive 7. Hard disk drive 7 is now defunct.
May also be shown as 806f010d0407ffff or 0x806f010d0407ffff
Severity
Error
Serviceable
Yes
Automatically notify support
Yes
Alert Category
370