Yes
Automatically notify support
Yes
Alert Category
Critical - Other
SNMP Trap ID
50
CIM Information
Prefix: PLAT ID: 0330
User Response
This is a UEFI detected event. To find the UEFI diagnostic code for this event, in the information
center, follow the instructions in "Finding the UEFI diagnostic code" under "UEFI diagnostic
codes." Then, in the information center, open the topic for the UEFI diagnostic code and follow the
instructions under "User response."
806f0021-2201ffff : Fault in slot [PhysicalConnectorSystemElementName] on system
[ComputerSystemElementName].
This message is for the use case when an implementation has detected a Fault in a slot. No Op ROM
Space.
May also be shown as 806f00212201ffff or 0x806f00212201ffff
Severity
Error
Serviceable
Yes
Automatically notify support
Yes
Alert Category
Critical - Other
SNMP Trap ID
50
CIM Information
Prefix: PLAT ID: 0330
User Response
This is a UEFI detected event. To find the UEFI diagnostic code for this event, in the information
center, follow the instructions in "Finding the UEFI diagnostic code" under "UEFI diagnostic
codes." Then, in the information center, open the topic for the UEFI diagnostic code and follow the
instructions under "User response."
806f0021-25820901 : Fault in slot [PhysicalConnectorSystemElementName] on system
[ComputerSystemElementName].
This message is for the use case when an implementation has detected a Fault in a slot. All PCI Error.
One of PCI Error.
.