Lenovo Flex System x220 Installation And Service Manual page 317

Compute node
Hide thumbs Also See for Flex System x220:
Table of Contents

Advertisement

User Response
Complete the following steps until the problem is solved: 1. Check the Chassis Management Module
or Flex System Manager event log for any fan- or cooling-related issues. 2. Make sure that the airflow
at the front and rear of the chassis is not obstructed and that fillers are in place and correctly installed.
3. Make sure that the room temperature is within operating specifications.
• 80070101-3702ffff : Sensor PEN Inlet Over T has transitioned from normal to non-critical state.
The PCIe Expansion Node Inlet temperature has exceeded its specified threshold.
May also be shown as 800701013702ffff or 0x800701013702ffff
Severity
Warning
Serviceable
Yes
Automatically notify support
No
Alert Category
Warning - Temperature
SNMP Trap ID
12
CIM Information
Prefix: PLAT ID: 0520
User Response
Complete the following steps until the problem is solved:
1. Check the Chassis Management Module or Flex System Manager event log for any fan- or
cooling-related issues.
2. Make sure that the airflow at the front and rear of the chassis is not obstructed and that fillers
are in place and correctly installed.
3. Make sure that the room temperature is within operating specifications.
• 8007010f-2201ffff : Sensor TXT ACM Module has transitioned to critical from a less severe state.
This message is for the use case when an implementation has detected a Sensor transitioned to critical
from less severe.
May also be shown as 8007010f2201ffff or 0x8007010f2201ffff
Severity
Warning
Serviceable
Yes
Automatically notify support
No
.
Chapter 6
Troubleshooting
309