3.3.4. Adjustments, display and weld data

The display for wire feed speed, welding voltage or material group. This can be switched using
the button under the display (wire feed speed/length of arc). The voltage can be adjusted in the
normal and 1-MIG position (wire feed range/the length of arc). During pulse welding the voltage
is determined by the wire feed speed while the length of arc affects some other parameters.
When pressed simultaneously, the weld data buttons recall the wire feed speed on the display, the
welding voltage and welding current values which have been used when welding was stopped.

3.3.5. Timer

intermittent welding
spot welding
The spot time is set immediately after pressing the switch button, on the display SPt.
The pause time is set accordingly, on the PSE display. The time is set using the Process
Manager.

3.3.6. Adjustment of welding dynamics

For adjusting of MIG/MAG welding dynamics, the adjustment value dyn -9...0...9 is
displayed. The welding stability and quantity of spatter are affected by the welding
dynamics control, the 0-position is the recommended reference range. Values -9...-1
give a smoother arc and less spatter, while values 1...9 give a rougher arc and increased
stability, when using a 100% CO ² shielding gas when welding steel.

3.3.7. Remote control

Gun control, wire feed speed or welding power control is changed using RMT 10.
Control of the welding voltage or the length of the welding arc can be adjusted using
the potentiometer on the panel. Panel control, adjustments using the potentiometer on
the panel.

3.3.8. Mig extra functions

Crater filling, 1-MIG and pulse MIG:
Crater filling reduces welding mistakes caused by end craters. By pressing the 4T-trigger
continuously at the end of weld, a descending welding power is achieved which fills end
craters in a controlled manner. The descending time is kept constant using the 2T function,
and the welding power and end level can be changed using the SETUP-function.
© Kemppi oy
Display for welding current and welding material
thickness. Changing can be made using the button
behind the display. There is a percentage display
(eg. gas consistency) and seconds display (see
timer). The relative length of arc will be displayed
when adjusted. Otherwise the predicted current
value is displayed (not in 2-MIG).
Process Manager™ for setting all welding
parameters.