6. TECHNICAL DATA
kempact Pulse 3000
Mains connection
Connected load
Mains cable/fuse
Load capacity
Adjustment range
wire feed speed
Open circuit voltage
Power ratio
Efficiency
Filler wires
Shielding gas
wire spool diameter
Feed roll Ø
Thermal class
Dimensions
weight
Gun connector
Principle of operation
Cooling unit kempactCool 10
Connection voltage
Connection capacity
Cooling power
Start pressure, max
Cooling liquid
Reservoir volume
External dimensions
weight
kempact Pulse 3000 and Cooling unit kempactCool 10
Range of temperature for use
Storage temperature for use
Degree of protection
The products meet conmormity reguirements for CE marking.
– Kempact pulse 3000, Kempactcool 10 / 0813
3~400v +/-15%, 50/60hz
40% eD
12 kvA 250A
60% eD
10 kvA 207A
100% eD
7,5 kvA 160A
4x1,5 mm² - 5 m/16A delayed
40% eD
250A /26,5v
60% eD
207A /24v
100% eD
160A /22v
8 - 30v
1 - 18 m/min
56 v
0,69 (250A / 26v)
0,84 (250A / 26v)
Fe, ss
0,6 ... 1,2 mm
Cored wire
0,9 ... 1,2 mm
Al
0,9 ... 1,2 mm
Cusi
0.8 ... 1,2 mm
Co ² , Ar, Ar & Co ² mixed gases
300 mm (15 kg)
32 mm
h (180 °C) / b (130 °C)
length
580 mm
width
280 mm
height
440 mm
22 kg
eURo
4-wheel feed
400 v - 15 % ... 10 %
250 w
1 kw
4,5 bar
20 % - 40 % etanol/water
n. 3 l
length
580 mm
width
280 mm
height
300 mm
13 kg
- 20 °C ...+ 40 °C
- 40 °C ...+ 60 °C
Ip23C
© Kemppi oy