Cable calibration
(MIG only)
Water cooler
Cycle timer
- Cycle timer time
WF end step
Weld data duration
Safe wire inch
(MIG only)
Gas guard (Master M 323 only)
Voltage display
Wire inch
Gas test
Language
PIN code
Device info
Factory reset

3.3.8 Control panel: Weld data

After each weld, a weld summary is displayed briefly. To change the weld data view duration, refer to "Control panel: Sys-
tem settings" on the previous page.
© Kemppi
Start/Cancel
OFF/Auto/ON
Default = Auto
ON/OFF
Default = OFF
0.0 ... 60.0 s
Default = 2.0 s
OFF/ON
Default = OFF
0...10 s, step 1
Default = 5 s
OFF/ON
Default = ON
ON/OFF
Default = OFF
Arc voltage / Terminal voltage
Default = Arc voltage
0.5 ... 18.0 m/min
Default = 5.0 m/min
0 ... 60 s
Default = 20 s
Available languages
ON/OFF
Reset/Cancel
Default = Cancel
45
Operating manual - EN
Calibration information on the previous
calibration is also shown. Refer to "Cal-
ibrating welding cable" on page 35 for
cable calibration.
When ON is selected, the coolant is cir-
culated continually, and when Auto is
selected, the coolant is circulated only
during welding.
A welding function that automatically
produces a weld of a predefined dur-
ation.
Wire feed end step feature prevents the
filler wire from sticking to the contact tip
when the welding ends.
This defines how long the weld data sum-
mary is shown after each weld.
When ON, and the arc doesn't ignite, the
filler wire is fed 5 cm. When OFF, 5 m of
filler wire is fed.
Gas guard prevents welding without
shielding gas.
This defines which is shown on the con-
trol panel display, arc or terminal voltage.
Drive the filler wire forward (with arc off).
Test the shielding gas flow and flush the
gas line.
4-digit PIN code for locking the control
panel after 30 s of inactivity. PIN lock does
not prevent welding, browsing Powerlog
levels or selecting memory channel.
Shows information on the device and its
usage.
Restores factory settings. Note that the
arc verification parameter value is also
reset.