Sony CCP-8000 System Setup Manual page 63

Hide thumbs Also See for CCP-8000:
Table of Contents

Advertisement

B) Set VLAN
In Case of Cisco Catalyst 2900-XL Series or Cisco Catalyst 3500-XL Series
VLAN is set on network through a standard browser such as Microsoft Internet Explorer or Netscape
Navigator/Communicator.
For details, refer to Quick Start Guide supplied with an Ethernet switch.
Step 1 : Disable Cisco Discovery Protocol (CDP)
To disable CDP requires Cisco Command Line Interface (CLI).
There are two ways to use CLI.
. Connect PC to a node of Ethernet switch with Ethernet cable. Access Ethernet switch through telnet.
. Connect the COM port of PC to the console port of Ethernet switch in the same manner as initial
setting. Access Ethernet switch.
1) Log in to Cisco Ethernet switch.
2) The prompt "CiscoSW1>" is displayed.
3) Enter the enable <cr>.
4) The prompt "CiscoSW1 #" is displayed.
5) Enter the configure terminal and [Enter].
6) The prompt "CiscoSW1 (config) #" is displayed.
7) Enter no cdp run and [Enter]
8) Enter end and [Enter].
9) The prompt "CiscoSW1 #" is displayed.
10) Enter show running-config prompt and [Enter].
11) Check to see "no cdp run" on monitor.
12) Enter write memory and [Enter].
13) Saved the setting on Cisco Ethernet switch.
14) Enter disable and [Enter].
15) The prompt "CiscoSW1>" is displayed.
16) Enter exit <cr> to exit telnet.
Step 2 : Set VLAN
n
If separated Ethernet switches are used for each of Control LAN, Data LAN and Peripheral LAN, it does
not require.
It requires to separate from each network, Control LAN, Data LAN, and Peripheral LAN to set VALN.
Use port 1 through 10 for Control LAN, port 11 through 20 for Data LAN, after 21 port for Peripheral
LAN.
For details, refer to Software Configuration Guide.
Assign port 1 through 10 to VLAN1, port 11 through 20 for VLAN2, port 21 through 24 for VLAN3.
Step 3 : Disable Spanning-Tree on VLANs
Connect PC to a node of Ethernet switch with Ethernet cable.
Browser requires to setup as Quick Start Guide
1) Access the Ethernet switch via PC
2) Open Cluster Management Suite of the switch.
3) Disable Spanning-tree protocol as Software Configuration Guide.
n
Save new configuration data.
If new configuration is not saved, the setting is back when re-booting.