Sony CCP-8000 System Setup Manual page 53

Hide thumbs Also See for CCP-8000:
Table of Contents

Advertisement

Connecting procedure
1. Remove the module cover. Remove the screws (BV3
x 10) fixing the caps (L) and (R), and remove the caps
in the direction of the arrow.
2. Loosen the four screws (with drop-safe) fixing the
operation module.
3. Hold the two screws (with drop-safe) in the front of
the both sides of the operation module, and remove the
operation module.
Module covers
Cap (L)
BV3 x 10
Screws
(with drop-safe)
Operation module
4. Remove the screws (BV3 x 10) fixing the side plates
to the adaptor case, and remove the side plates.
BV3 x 10
Adaptor case
MVS-8000 System
SYSTEM SETUP
Screws
(with drop-safe)
BV3 x 10
Cap (R)
Side plates
BV3 x 10
When the Vertical connection is selected
(1) Connect the adaptor cases that you want to connect, together.
(Be careful of the direction of the adaptor cases. See the
instruction given on the bottom of the adaptor case.)
(2) Fix the right and left of the adaptor cases as shown in the
illustration using the two pieces of the connecting plate C.
. When fixing the adaptor cases, you can select either the
flat connection or the connection like flight of steps.
. When selecting the connection like flight of steps of
the connection method (A), (see Fig. 2) the two
screws are secured with one notch offset each other.
. When the flat connection of the connection method
(B, C) is selected, (see Fig. 2) the two screws are
secured in the same height.
Adaptor cases
Connecting
plate C
BV 3 x 10
When the Horizontal connection is selected
(1) Connect the adaptor cases that you want to connect,
together.
(Be careful of the direction of the adaptor cases. See the
instruction given on the bottom of the adaptor case.)
(2) Fix the top plate of the adaptor cases at the locations
shown in the illustration using the two connecting
screws and the two pieces of the connecting plate A
for every two pieces of adaptor case.
BV3 x 10
Instruction given on the
bottom of the cases
2-8. CCP-8000 Panel Cabling
Instruction given on
the bottom of the case
Connecting
BV 3 x 10
plate C
BV3 x 10
Connecting plates A
Adaptor cases
2-23

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Mve-8000Mvs-8300Dcu-8000Mvs-8400Mvs-8000Mvs-8200

Table of Contents