75
Inflating the Tube
1) Ensure that the valve is positioned perpendicularly for proper positioning of the tube and tyre in the region of
the valve.
2) Firmly screw on the valve nut.
3) Inflate the tube so that the tyre can still be pressed in easily with your thumb.
INFORMATION: If the circumferential lines on the two sides of the tyre are both at an even distance
from the rim, the tyre is centred. If not, let some air out and realign the tyre.
4) Inflate the tube to the maximum pressure specified by the tyre manufacturer (see information printed on the
casing).
5) Firmly screw the valve cap onto the valve.
7.2.2 Special Case of Wheels with PU Tyres
If the PU tyres have to be replaced, the entire wheel also has to be replaced on both sides (in pairs).
8 Disposal
8.1 Disposal Information
Return the product to the specialist dealer for disposal.
All components of the product must be disposed of properly in accordance with the respective national environ
mental regulations.
9 Legal Information
9.1 Service life
Based on market observations and the current state of technology, the manufacturer has calculated that the
product can be used for a period of 5 years, provided that it is used properly and that the service and maintenance
instructions are followed. Storage times at the dealer or with paying parties are not included in this period.
However, we would like to emphasise that the product is reliable far beyond this defined period of time, provided
that it is cared for and maintained properly.
If the service life is reached, the user or a responsible attendant should contact the qualified personnel who fitted
the product or the manufacturer's service (see inside or outside of rear cover for address).
9.2 Liability
The manufacturer's warranty applies only if the device has been used under the conditions and for the purpose
described. The manufacturer recommends that the device be used and maintained according to the instructions for
use.
The manufacturer is not responsible for damages caused by components and spare parts not approved by the
manufacturer. Repairs must be carried out exclusively by authorised dealers or by the manufacturer.
9.3 CE Conformity
This device meets the requirements of the 93/42/EEC guidelines for medical devices. This product has been clas
sified as a class I device according to the classification criteria outlined in appendix IX of the directive. The declara
tion of conformity was therefore created by Ottobock with sole responsibility according to appendix VII of the
guidelines.
discovery tmax
76
Disposal
Ottobock | 37