Daikin CMSQ200A7W1B Service Manual page 96

Hide thumbs Also See for CMSQ200A7W1B:
Table of Contents

Advertisement

SiBE28-805
3.1.4 Setting Contents and Code No. – Indoor unit
Mode
Setting
No.
Switch
No.
Note 2
Filter contamination heavy/
light (Setting for display
time to clean air filter)
0
(Sets display time to clean
air filter to half when there
is heavy filter
contamination.)
1
Long life filter type
2
Thermostat sensor in remote controller
10
(20)
Display time to clean air filter calculation
3
(Set when filter sign is not to be displayed.)
Information to i-Manager, i-Touch
5
Controller
6
Thermostat sensor in group control
Optional accessories output selection (field
0
selection of output for adaptor for wiring)
ON/OFF input from outside (Set when ON/
1
Indoor
OFF is to be controlled from outside.)
unit
Thermostat differential changeover
settings
2
(Set when remote sensor is to be used.)
3
OFF by thermostat fan speed
12
(22)
Automatic mode differential
(automatic temperature differential
4
setting for system heat recovery
series cool/heat)
5
Power failure automatic reset
6
Airflow When Cooling Thermostat is OFF
9
Fixed cool/heat master
High air outlet velocity
0
(Set when installed in place with
ceiling higher than 2.7 m.)
Selection of airflow direction (Set when a
1
13
blocking pad kit has been installed.)
(23)
4
Field set airflow position setting
Setting the external static pressure
6
(To be set in function of the
connected duct resistance)
1
Thermostat OFF excess humidity
Direct duct connection
(when the indoor unit and heat
2
reclaim ventilation unit are
15
connected by duct directly.) ∗Note 6
(25)
3
Drain pump humidifier interlock selection
Field set selection for individual
5
ventilation setting by remote controller
Notes :
1. Settings are made simultaneously for the entire group, however, if you select the mode No.
2. The mode numbers inside parentheses cannot be used by wireless remote controllers, so
3. Marked
4. Do not make settings other than those described above. Nothing is displayed for functions
5. "88" may be displayed to indicate the remote controller is resetting when returning to the
6. If the setting mode to "Equipped", heat reclaim ventilation fan conducts the fan residual
7. If setting 10-6-01 + 10-2-01 or 10-2-02 or 10-2-03 are set at the same time, then setting for
8. Only use in combination with optional remote sensor or when setting 10-2-03 is used.
Test Operation
Setting Contents
Super
long life
filter
Long life filter
Standard filter
inside parentheses, you can also set by each individual unit. Setting changes however
cannot be checked except in the individual mode for those in parentheses.
they cannot be set individually. Setting changes also cannot be checked.
are factory set.
the indoor unit is not equipped with.
normal mode.
operation by linking to indoor unit.
group connection, 10-6-01 has priority and for individual connection, 10-2-01, 10-2-02 or 10-
2-03 have priority.
Second Code No.(Note 3)
01
02
Approx.
Approx.
10,000 hrs.
5,000 hrs.
Light
Approx.
Heavy
Approx.
2,500 hrs.
1,250 hrs.
Approx.
Approx.
200 hrs.
100 hrs.
Super long life
Long life filter
filter
Use
No use
Display
No display
Only unit sensor value
Sensor value as
(or remote sensor value
set by 10-2-0X
if installed).
or 10-6-0X.
Use both the unit
Use unit sensor
senor (or remote
only (or remote
sensor if installed)
sensor if
AND the remote
installed).
controller sensor.
(See note 7)
(See note 4+5+6)
Indoor unit turned
ON by thermostat
Forced OFF
ON/OFF control
1°C
0.5°C
LL
Set fan speed
01:0
02:1
03:2
04:3
Not equipped
Equipped
LL airflow
Preset airflow
Disabled
Enabled
N
H
F (4 directions)
T (3 directions)
Draft prevention
Standard
High static
Normal
pressure
Not equipped
Equipped
Not equipped
Equipped
Not equipped
Equipped
Not equipped
Equipped
Field Setting
03
04
Operation
Malfunction
output
output
External protection
device input
OFF (See note 8)
05:4
06:5
07:6
08:7
S
W (2 directions)
Ceiling Soiling prevention
Low static
pressure
Details
No.
(1)
(2)
(3)
(4)
(5)
(6)
(7)
(8)
(9)
(10)
(11)
(12)
(13)
(14)
(15)
(16)
(17)
(18)
(19)
85

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Fmdq50-125a7v3bCmsq250a7w1bFmcq50-125a7veb

Table of Contents