Sign In
Upload
Manuals
Brands
Daikin Manuals
Heat Pump
FMCQ50-125A7VEB
Daikin FMCQ50-125A7VEB Manuals
Manuals and User Guides for Daikin FMCQ50-125A7VEB. We have
1
Daikin FMCQ50-125A7VEB manual available for free PDF download: Service Manual
Daikin FMCQ50-125A7VEB Service Manual (280 pages)
Brand:
Daikin
| Category:
Heat Pump
| Size: 7.77 MB
Table of Contents
Cms R-410A Heat Pump 50Hz
2
Table of Contents
2
Safety Cautions
7
Part 1 General Information
12
1 Model Names of Indoor/Outdoor Units
13
2 External Appearance
14
Indoor Units
14
Outdoor Units
14
3 Combination
15
Combination Overview
15
Combination Matrix
15
4 Model Selection
16
Part 2 Specifications
18
Specifications
19
Indoor Units
22
Part 3 Refrigerant Circuit
26
1 Refrigerant Circuit
27
Cmsq200A7
27
Cmsq250A7
29
2 Functional Parts Layout
31
Cmsq200A7
31
Cmsq250A7
32
Cooling Operation
33
3 Refrigerant Flow for each Operation Mode
33
Part 4 Function
42
1 Function General
43
Symbol
43
Operation Mode
44
2 Basic Control
45
Normal Operation
45
Compressor PI Control
46
Electronic Expansion Valve PI Control
48
Step Control of Outdoor Unit Fans
48
Outdoor Unit Fan Control in Cooling Operation
49
3 Special Control
50
Startup Control
50
Oil Return Operation
51
Defrosting Operation
53
Pump-Down Residual Operation
54
Standby
55
Crankcase Heater Control
55
Restart Standby
55
Stopping Operation
56
4 Protection Control
58
High Pressure Protection Control
58
Low Pressure Protection Control
59
Discharge Pipe Protection Control
60
Inverter Protection Control
61
Injection Control (Only for CMSQ200A7)
62
5 Other Control
63
Demand Operation
63
Heating Operation Prohibition
63
6 Outline of Control (Indoor Unit)
64
Drain Pump Control
64
Louver Control for Preventing Ceiling Dirt
66
Thermostat Sensor in Remote Controller
67
Thermostat Control While in Normal Operation
69
Thermostat Control in Dry Operation
69
Electronic Expansion Valve Control
70
Hot Start Control (in Heating Operation Only)
70
Freeze Prevention
71
Heater Control
71
List of Swing Flap Operations
72
Test Operation Part 5
74
Part 5 Test Operation
74
Test Operation Part
75
1 Test Operation
75
Installation Process
75
Procedure and Outline
76
Leak Test and Vacuum Drying
78
Charging Refrigerant
79
Pipe Insulation
79
Important Information Regarding the Refrigerant Used
80
Additional Refrigerant Charge
83
Before Operation
84
Service Precautions
84
Service Mode Operation
90
Operation When Power Is Turned on
91
2 Outdoor Unit PC Board Layout
92
3 Field Setting
93
Field Setting from Remote Controller
93
Detailed Explanation of Setting Modes
98
Field Setting from Outdoor Unit
107
Part 6 Troubleshooting
130
1 Symptom-Based Troubleshooting
132
2 Troubleshooting by Remote Controller
135
The INSPECTION / TEST Button
135
Self-Diagnosis by Wired Remote Controller
136
Self-Diagnosis by Wireless Remote Controller
137
Remote Controller Service Mode
140
Remote Controller Self-Diagnosis Function
142
A0" Indoor Unit: Error of External Protection Device
149
3 Troubleshooting by Indication on the Remote Controller
149
A1" Indoor Unit: PC Board Defect
150
A3" Indoor Unit: Malfunction of Drain Level Control System (S1L)
151
A6" Indoor Unit: Fan Motor (M1F) Lock, Overload
153
A9" Indoor Unit: Malfunction of Moving Part of
154
Electronic Expansion Valve (Y1E)
154
AF" Indoor Unit: Drain Level above Limit
156
AJ" Indoor Unit: Malfunction of Capacity Determination Device
157
C4" Indoor Unit: Malfunction of Thermistor (R2T) for Heat Exchanger
158
C5" Indoor Unit: Malfunction of Thermistor (R3T) for Gas Pipes
159
Sibe28
159
C9" Indoor Unit: Malfunction of Thermistor (R1T) for Suction Air
160
CC" Indoor Unit: Malfunction of Humidity Sensor System
161
CJ" Indoor Unit: Malfunction of Thermostat Sensor in Remote Controller
162
E1" Outdoor Unit: PC Board Defect
163
E3" Outdoor Unit: Actuation of High Pressure Switch
164
E4" Outdoor Unit: Actuation of Low Pressure Sensor
166
E5" Outdoor Unit: Inverter Compressor Motor Lock
168
E7" Outdoor Unit: Malfunction of Outdoor Unit Fan Motor
170
E9" Outdoor Unit: Malfunction of Moving Part of
173
Electronic Expansion Valve (Y1E, Y2E)
173
F3" Outdoor Unit: Abnormal Discharge Pipe Temperature
175
F6" Outdoor Unit: Refrigerant Overcharged
176
H7" Outdoor Unit: Abnormal Outdoor Fan Motor Signal
177
H9" Outdoor Unit: Malfunction of Thermistor (R1T) for Outdoor Air
178
J3" Outdoor Unit: Malfunction of Discharge Pipe Thermistor (R3T)
179
J5" Outdoor Unit: Malfunction of Thermistor (R2T, R7T) for Suction Pipe
180
J6" Outdoor Unit: Malfunction of Thermistor (R4T) for Outdoor Unit Heat Exchanger
181
J7" Outdoor Unit: Malfunction of Liquid Pipe Thermistor (R6T)
182
Gas Pipe Thermistor (R5T)
183
J9" Outdoor Unit: Malfunction of Subcooling Heat Exchanger
183
JA" Outdoor Unit: Malfunction of High Pressure Sensor
184
JC" Outdoor Unit: Malfunction of Low Pressure Sensor
185
L4" Outdoor Unit: Malfunction of Inverter Radiating Fin Temperature Rise
186
L5" Outdoor Unit: Inverter Compressor Abnormal
188
L8" Outdoor Unit: Inverter Current Abnormal
190
L9" Outdoor Unit: Inverter Start up Error
192
Inverter and Control PC Board
194
LC" Outdoor Unit: Malfunction of Transmission between
194
P1" Outdoor Unit: Inverter Over-Ripple Protection
197
P4" Outdoor Unit: Malfunction of Inverter Radiating Fin Temperature Rise Sensor
198
PC Board or Faulty Combination of PC Board
200
U0" Outdoor Unit: Low Pressure Drop Due to Refrigerant Shortage or Electronic Expansion Valve Failure
201
U1" Reverse Phase, Open Phase
202
U2" Outdoor Unit: Power Supply Insufficient or Instantaneous Failure
203
U3" Outdoor Unit: Check Operation Not Executed
206
U4" Malfunction of Transmission between Indoor Units
207
U5" Indoor Unit: Malfunction of Transmission between Remote Controller and Indoor Unit
209
U7" Indoor Unit: Malfunction of Transmission between Outdoor Units
210
U8" Indoor Unit: Malfunction of Transmission between Main and Sub Remote Controllers
212
U9" Indoor Unit: Malfunction of Transmission between Indoor and Outdoor Units in the same System
213
Indoor Units and Remote Controller
214
UA" Improper Combination of Indoor and Outdoor Units
214
UC" Address Duplication of Centralized Controller
216
UE" Malfunction of Transmission between Centralized Controller and Indoor Unit
217
UF" System Is Not Set yet
220
UH" Malfunction of System, Refrigerant System Address Undefined
221
M1" PC Board Defect
223
M8" Malfunction of Transmission between Optional Controllers for Centralized Control
224
MA" Improper Combination of Optional Controllers for Centralized Control
226
MC" Address Duplication, Improper Setting
228
4 Troubleshooting (OP: Central Remote Controller)
223
5 Troubleshooting (OP: Unified ON/OFF Controller)
231
Operation Lamp Blinks
231
Display "Under Centralized Control" Blinks (Repeats Single Blink)
233
Display "Under Centralized Control" Blinks (Repeats Double Blink)
236
Part 7 Appendix
240
1 Piping Diagrams
241
Outdoor Unit
241
Indoor Unit
243
2 Wiring Diagrams for Reference
244
Outdoor Unit
244
Field Wiring
246
Indoor Unit
247
Wiring Diagrams for Reference
248
3 List of Electrical and Functional Parts
250
Outdoor Unit
250
Indoor Side
251
4 Option List
252
Option List of Controllers
252
System Configuration
253
Option Lists (Outdoor Unit)
254
5 Example of Connection (R-410A Type)
256
6 Thermistor Resistance / Temperature Characteristics
258
7 Pressure Sensor
260
8 Method of Checking the Inverter's Power Transistors and Diode Modules
261
Diode Modules
261
Part 8 Precautions for New Refrigerant (R-410A)
264
Precautions for New Refrigerant (R-410A)
265
Outline
265
Refrigerant Cylinders
267
Service Tools
268
Advertisement
Advertisement
Related Products
Daikin FMDQ50-125A7V3B
Daikin FXAQ50MA
Daikin FXNQ32MA
Daikin FVXS35RV1A
Daikin FV125LAVE
Daikin FDXS35EV2C
Daikin Altherma FWXM20AATV3R
Daikin FWE11DAFN5V3-R
Daikin FXDQ25M8
Daikin FXZQ32M8
Daikin Categories
Air Conditioner
Heat Pump
Remote Control
Chiller
Fan
More Daikin Manuals
Login
Sign In
OR
Sign in with Facebook
Sign in with Google
Upload manual
Upload from disk
Upload from URL