Table 5‑6. Data logger parameters
Parameter Number
P450.00
P451.00
P452.00-39
P453.00-39

To Configure the Data Logger Settings

    
1. Press the F1 button to display the main menu.
2. Press the ▼ button until Configuration is highlighted, and then press the enter
button.
3. Press the ▼ button until Extended is highlighted, and then press the enter
button.
4. Press the ▼ button until Numerical List is highlighted, and then press the
enter button.
5. To navigate to a specific parameter, use the ▲ and ▼ buttons to highlight the
parameter, and then press the enter button.
a. Use the ◄ and ► buttons to highlight specific numbers.
b. Use the ▲ and ▼ buttons to change the number value.
570-1003552-05A
Parameter Definition
Data logger on or off
Data logger time interval
Parameter number data
logger
Indices data logger
Advanced Energy® AE 3TL Inverters
Switches the data logger
on and off:
• 0: Off
• 1: On (data is
Contains the time interval
(60, 300, 600 seconds)
frequency at which the
data logger saves data.
Contains a list of all
parameter numbers that
are to be recorded. This
only works in conjunction
with the indices (P453.x).
Parameter numbers that do
not exist are ignored.
Contains a list of all
indices for the parameter
numbers that are to be
recorded. This only works
in conjunction with the
parameter numbers
(P452.x). Parameter
numbers that do not exist
are ignored.
Operating
Description
recorded regularly)
5‑17