Data Logger; Table 5-5. Data Storage - Advanced Energy AE 3TL 600 Series Installation And Operation Manual

Table of Contents

Advertisement

Advanced Energy
4. Use the ▲ and ▼ buttons to select the following:
◦ Activation:
▪ 0 = off
▪ 1 = on
◦ Send configuration:
▪ 0 = no configuration data in the queue
▪ 1 = configuration data being sent
◦ Server IP: Displays the server IP address
◦ Server port: Displays the port number of the web server
◦ Portal test: Yes sends a data packet to the web server (portal). There is no
acknowledgement. To verify that the data packet was sent, contact AE Solar
Energy Technical Support.
◦ Password:
◦ Extended:
5. Press the enter button to confirm each of the above settings.
6. Press ESC to return to the main menu.

DATA LOGGER

   
The inverter contains an internal data logger which records measured values while
the inverter is running. The data logger uses a circular buffer, which means that when
the memory is full, the oldest data is overwritten. The default configuration includes
16 measurement channels.
Table 5‑5. Data storage
1 minute
5 minutes
10 minutes
The following parameters are used to set the data logger.
5‑16
Logging Cycle
Operating
Length of Storage Time
6 months
2.5 years
5 years
570-1003552-05A