ELECTRICAL

Fuses

Location

-
The main 30 Amp fuse (A) is located near the starter
solenoid and kill relay.
-
The charging system 25 Amp fuse (B) is located
under the RH control panel.
-
The optional accessory 15 Amp fuse (C) is located
under the RH control panel.
B

How It Works

The fuses protect the electri cal system from electrical
surges.
7
7-16
C
Fig. 135
PICT-3044

Testing

With a multimeter set to OHM of continuity setting,
check the continuity between the fuse blades. If the
fuse is OPEN, replace it and test the circuit.
The fuses used in this application can also be
visually inspected. A failed fuse can be identified by
the broken/melted element inside the fuse cover or a
damaged spade (Fig. 136 and Fig. 137).