Connection between the HP 10320A/
HP 10321A and the target system is
accomplished by selecting one of the
three dual in-line connectors shown
below.
Dual In-line
HP Model
Connector
Number
40-pin
10322A
48-pin
10323A
64-pin
10324A
User convenience is enhanced by
demultiplexing address and data signals
on the interface board and with user
labels in the logic analyzer. State,
timing, and analog (HP 1631A/D) labels
and symbols can be loaded into the logic
analyzer to simplify data interpretation
and reduce measurement errors .
General Specifications
Power
Requirements
0 .4 A at +5 Vdc max
drawn from the I-IP 1630/1631 .
0 .8 A at +5 Vdc max drawn
from the HP 1630/1631 .
1 .0 A at +5 Vdc max drawn
from the HP 1630/1631 .
0 .4 A at +5 Vdc max
drawn from the HP 1630/1631 .
0 .30 A at +5 Vdc max
drawn from the HP 1630/1631 .
1 .0 A at +5 Vdc max
drawn from the HP 1630/1631 .
0 .15 A drawn from target
system ; 1 .0 A at +5 V max
drawn from the HP 1630/1631 .
80286 microprocessor operating
current drawn from target
system ; 0.66 A at +5 Vdc max
drawn from the HP 1630/1631 .
0.1 A at +5 Vdc max
drawn from the HP 1630/1631 .
0.3 A at +5 Vdc max
drawn from the HP 1630/1631 .
0.5 A at +5 Vdc max
drawn from the HP 1630/1631 .
0 .5 A at +5 Vdc max
drawn from the HP 1630/1631 .
ENVIRONMENTAL
Temperature : operating, 0° to +55° C (+32° to +131° F) .
Non-operating, -40° to + 75° C (-40° to +167° F) for all modules .
Altitude: operating, up to 4600 m (15 000 ft) . Non-operating, up to 15 300 m (50 000 ft).
Humidity : 90% non-condensing . Avoid sudden, extreme temperature change that could cause condensation
within the instrument .
Microprocessor
Maximum
Signal Line
(Interface
Clock Speed Loading
Module)
(MHz)
MOTOROLA
6800/02
2
1 LS TTL load/line
(HP 1030713)
+ approx . 35 pF .
6809/6809E
2
1 LS TTL load/line
(HP 1030813)
+ approx . 35 pF .
68000/68010
12.5
1 LS TTL load/line
(HP 1031113)
+ approx . 35 pF .
68008
12.5
1 LS TTL load/line
(HP 1031013)
+ approx . 35 pF .
INTEL
8085
6
1 LS TTL load/line
(HP 1030413)
+ approx . 35 pF .
8086/88
10
Clock Input 2 LS TTL loads/line
(HP 1030513)
+ approx . 40 pF; 1 LS TTL
load/line for all others .
80186/88
8
ADO-15, A16-19, BHE 1 LS
(HP 1030613)
TTL load + approx . 40 pF .
CLKOUT, HLDA, SO, S1,
2 TTL loads + approx . 40 pF .
All others, no load + approx .
12 pF.
80286
20
SO, S1, DO-D15 and HLDA,
(HP 1031213)
one "F" Load + approx .
40 pF capacitance ; AO-A23,
BHE, M/10, COD/INTA,
LOCK RESET, and READY,
one ALS load + approx . 40 pF
capacitance; all other signals, no
load + approx . 12 pF capacitance .
NATIONAL
NSC800
4
1 HCMOS load/line
(HP 1030313)
+ approx. 35 pF .
ZILOG
Z80
6
1 LS TTL load/line
(HP 1030013)
+ approx. 35 pF .
Z8001
8
1 LS TTL load/line
(HP 1030113)
+ approx . 35 pF .
Z8002
8
1 LS TTL load/line
(HP 1030213)
+ approx . 35 pF .