Model 1630A/D/G
Display Messages
INSERT to check for disc - This message is displayed when the cursor is in the top row of the Storage
Operations menu . Pressing INSERT will cause the analyzer to see if a disc is present at the assigned HP-IB
address and unit.
INSERT to confirm - Before the current operation can continue, INSERT must be pressed to confirm that the
selected operation is desired .
INSERT to inverse assemble-This message is displayed in thestate list menu when certain inverse assemblers
are active. the current inverse assembler cannot accurately determine where the first state of an instruction
fetch is . Position the display so that the state aligned with the inverse video line number is the first state of an
instruction fetch . Press INSERT to start the inverse assembly from the indicated state .
INSERT to overwrite -A request has been made to overwrite a disc file. Before the old file is destroyed, INSERT
must be pressed to overwrite it.
INSERT to start operation - This message is displayed when the cursor is in the bottom row of the Storage
Operations menu . Pressing INSERT will cause the analyzer to begin the currently selected operation .
INSERT to store compare image -This message is displayed in the state full compare list menu when viewing
the trace data . Press INSERT to store the current trace data as the compare image.
Internal message error - Indicates internal problems with the analyzer . Record events leading up to this
message and contact Hewlett-Packard .
Invalid clock setting - This message is displayed when the analyzer clock in the SYSTEM [Peripherals] menu
has not been set to a correct date . The clock date must be later than December, 1981 .
NOTE: Compare list is empty-This message is displayed when the state Compare traced mode is selected and
the list in the compare memory has no entries .
NOTE : Cursor correlation is not available - This message will appear during interactive state/timing
measurements if conditions other than State Master and Timing Don't Care are set up. For example if state is
master and timing is set to trigger on a pattern or glitch .
NOTE : No stored compared image -This message is displayed when the state Full Compare mode is selected .
NOTE : Trace data has less states than compare image. This message is displayed in the trace compare modes
when the trigger is centered on, or ends the trace.
NOTE : Trace data has more states than compare image. This message is displayed in the trace compare
modes when the trigger is centered on, or ends the trace.
Max 43 "'s per label - State format labels can have a maximum of 43 bits allocated .
One " ' required for each label - This message is displayed when a name for a new label has been created
before assigning the first bit to be identified by that label .
Operation aborted - The current operation has been aborted . Example : occurs when STOP is pressed during a
save configuration to internal storage.
Power-up complete - This message is displayed after the analyzer has successfully completed the power-up
test routine .
Reading directory - The analyzer is reading the directory on the external mass storage device .
ROLL to change configuration - This message is displayed when in the SYSTEM [Configuration] menu . It
prompts use of the ROLL keys to change the distribution of input bits between the state and timing
measurement channels .