Changing a used PRESET PLUG
1. Insert the PR
W7xx and then turn on the device. The P1 and R1 LEDs flash yellow to signal
that the PRESET PLUG was
2.
Start Web Based Management, there you will see the current settings of the
PRESET PLUG. Make the required changes to the configuration.
3.
In the Modify C-PLUG list box, s
4.
In the PRESET PLUG for box, specify the device for which you
the PRESET PLUG.
5.
Click on the Modify button to transfer the configuration o
PRESET PLUG.
6.
Turn the device off and remove the PRESET PLUG.
Using the
PRESET PLUG to commission a de
Note
To work correctly, the PRESET PLUG must have a content that matches the target
device.
1.
Insert the PRESET PLUG in the C-PLUG slot of the device to which you wan
to assign a configuration.
2.
Turn on the power to the device. The LEDs P1 and R1 (and R2 on a
SCALAN
PRESET PLUG was detected.
3.
Press the reset button beside the C-PLUG briefly to save the settings of the
PRESET PLUG on the device.
4.
When all the data has been transferred from the PRESET PLUG to the
device, the LEDs stop flashing and are permanently lit.
5.
Turn the device off and remove the PRESET PLUG.
Note
The next time the device starts up, it uses the settings from the PRESET PLUG
and the previous IP configuration.
Operating Instructions SCALANCE W78x
C79000-G8976-C184-07
ESET PLUG in the C-PLUG slot of a powered-down SCALANCE
detected.
CE W7xx with two wireless interfaces) flash yellow to signal that the
Description of the SCALANCE W78x
elect the Create P
RESET-PLUG entry.
vice
want to create
f the device to the
t
46

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Scalance w788-1rrScalance w788-2rrScalance w788-2pro

Table of Contents