Configuration Using Web Based Management and the Command Line Interface
6.7.4

Link Check Menu Command

Note
This function is not available in iPCF mode.
Device-Related Connection Monitoring
The Link Check function provides device-related connection monitoring for a
maximum of ten wireless nodes logged on at the SCALANCE W7
can be compared with the link on a wired connection. The function monitors
whether the nod
from the node or sent successfu
SCALANCE W78x attempts to send a test packet to the node.
Note
With the Link Check function, you can only monitor connections to WLAN clients;
use along with redundancy or WDS is not possible.
System Ev
ent for Connection Abort
You can specify how the SCALANCE W78
reestablishment of a connection) in the Sy
Operating Instructions SCALANCE W78x
C79000-G8976-C184-07
e is available over the wireless medium. If no packet is received
lly after half of the configured monitoring time, the
x reacts to a connection abort (or to the
stem > Events menu.