Configuration Using Web Based Management and the Command Line Interface
S
yntax of the Command Line Interface
CLI\IFEATU
RES\IP_ALIVE>
Command
ipalive <E|D>
add <E|D> <IP address>
<:Port> <Timeout>
edit <index|IP addr.>
[:port] [E|D]
[timeout]
delete <Index|IP addr.>
clearall
acknow [Index|all]
Operating Instructions SCALANCE W78x
C79000-G8976-C184-07
De
scription
Enables / disables application-
related connection monitoring.
Adds a new IP address to the
connection monitoring and enables
/ disables monitoring for this IP
address.
Modifies, enables, or disables the
entry specified by the index or IP
address.
Deletes the node to be monitored.
Deletes all entries for connection
monitoring.
Displays or acknowledges (clears)
the IP Alive messages requiring
acknowledgment.
Comment
The fault state remains
active until all the fault
messages have been
acknowledged. The fault
state and the Fault LED
are cleared if the only
reason was an IP Alive
error message. The
command is not visible in
the client mode.