Hydro-Gear ZT-2800 Hydrostatic Transaxles
Fig. 003
Lubrication
Oil Capacity ZT-2800
Oil Level Check
Fluid Change Interval
Checking the Hydraulic Oil Level
Fig. 004
A. Expansion reservoir
B. Full cold line
Toro TimeCutter SW/SWX Service Manual
PICT-1002
Toro HYPR-OIL 500 or 20w50 Engine Oil
77.23 fl. oz. (2284ml) each
Check expansion reservoir and if necessary add the specified oil to the FULL COLD
line. See illustration below. Also see the Hydro-Gear ZT-2800 service manual
(BLN-52441).
After the First 50 hours - change the oil and filters for the hydraulic system and bleed
the system.
Every 400 Hours - change the oil and filters for the hydraulic system and bleed the
system.
A
B
C
PICT-1003
C. Engine
SPECIFICATIONS
2
2-5