8. Remove the drive belt tensioner spring (Fig. 063).
Fig. 063
9. Slip the drive belt off the idler pulleys, then off the
appropriate hydro input pulley.
10. If equipped, disconnect and plug the hydro reservoir
hoses at the hydro fitting. Be sure to capture and
dispose of fluid and shop towels properly (Fig. 064).
(SWX only)
Fig. 064
Toro Timecutter SW/SWX Service Manual
HYDROSTATIC DRIVE SYSTEM
11. Remove the hydro center support:
Wide Frame – Remove the (6) mounting fasteners (Fig.
065).
PICT-1091
Narrow Frame – Remove the (4) mounting fasteners
(Fig. 066).
PICT-1104
12. Safely support hydro assembly in current position
using a hydraulic floor jack.
Fig. 065
PICT-1094
Fig. 066
PICT-1095