Example: When changing [Pixel Format]
Note
Direct entry of numerical and text values is possible for some setting items.

Configuring Exposure and External Trigger Settings

Configure settings related to exposure control methods and trigger control.
The factory settings are as follows. Change settings as necessary, according to the intended purpose
or application.
Factory default values
Trigger Selector (trigger operation)
Trigger Mode
Trigger Source (trigger signal source)
Trigger Activation (trigger polarity)
Exposure Mode
Exposure Time
Exposure Auto*
* This item is only enabled when [Exposure Mode] is set to [Timed].
Caution
When [Exposure Mode] is set to [Off], [Trigger Mode] cannot be set to [On]. Other settings may also be restricted
depending on the exposure mode, so be sure to set the exposure mode before configuring the trigger settings.
Adjusting Packet Size: With [Trigger Mode] set to [Off] and [Exposure Mode] set to [Continuous], clicking the (Start
Acquisition) button should produce a live image. If, however, you can only see a black screen, it may be the result
of the packet size setting in the camera being larger than the packet size setting in the GigE NIC or switch. To
correct the problem, you can either reduce the [Packet Size] setting to a value less than 1500 in the JAI Control
Tool (under [Transport Layer Control] / [Stream Channel Selector], or set your NIC or switch to support "Jumbo
Frames." This setting is typically found in the Advanced Adapter Settings for the NIC or switch which can be
accessed through the Device Manager on your PC.
Item
— 17 —
Default value
Frame Start
Off
Line 5 - Optical In 1
Rising Edge (rising edge of input signal)
Timed (control via exposure time)
30172 (µs)
Off