IAI GO-2401M-PGE User Manual page 11

2.35m digital progressive scan monochrome and color camera
Table of Contents

Advertisement

Recommended external output circuit diagram (reference example)
Standard circuit diagram example
User side
Userload
(resistor/lamp/relay/etc)
330~
OUT
2SC6033
USER POWER2
+5V to +24V
R1, R4 = 330 Ω PULL_UP
Time Delay Rise
Rise Time
Time Delay Fall
Fall Time
Characteristics of the recommended circuits for Opto OUT
OUTPUT LINE RESPONSE TIME
Camera
Output
Signal
Output
Line
Voltage
7 Camera locking screw holes (M3, 3 mm depth)
Use these holes when attaching an MP-43 tripod adapter plate (optional) or mounting the camera
directly to a wall or other structural system.
The smaller holes (×4) are M2 with a depth of 3 mm.
JAI
User
GO Series CAMERA
side
side
330
HIROSE_6Pin_NO.3 or 4
4k7
4k7
HIROSE_6Pin_No.5
2SC6033
3.3 V
TDR (µs)
0.78
RT (µs)
4.1
TDF (µs)
0.26
FT (µs)
1.3
RT
TDF
TDR
— 11 —
GO-2401M-PGE / GO-2401C-PGE
JAI camera
TLP109(TPR,E)
6
5
220BS
4
220BS
User power (Vcc)
5.0 V
12 V
0.82
1.8
4.7
6.1
0.48
0.56
1.6
3.1
FT
90%
Output LEVEL = User Vcc- (0.8 to 1.1)
10%
OUT f rom camera
1
180BS
3
100KBS
24 V
2.65
9.1
0.78
4.8

Advertisement

Table of Contents
loading

This manual is also suitable for:

Go-2401c-pge