IAI GO-2401M-PGE User Manual page 46

2.35m digital progressive scan monochrome and color camera
Table of Contents

Advertisement

Item
c) Acquisition Control
Acquisition Mode
Acquisition Start
Acquisition Stop
Acquisition Frame Count
Acquisition Frame Rate*
* Max. frequency/min. frame
period depends on ROI, pixel
format, and binning mode
selected.
Acquisition Frame Rate Raw*
* Max. frequency/min. frame
period depends on ROI, pixel
format, and binning mode
selected.
Trigger Selector
Trigger Mode
Trigger Software
Trigger Source
Trigger Activation
Trigger OverLap
Exposure Mode
Exposure Time
Exposure Time Raw
Exposure Auto
d) Event Control
Event Selector
Event Notification
e) Analog Control
Gain Selector
Gain
Setting range
Single Frame, Multi Frame,
Continuous
1 to 255
0.125 to 32.8423
30448 to 8000000
Acquisition Start,
Acquisition End, Frame Start,
Acquisition Transfer Start
Off, On
Low, High, Software,
Pulse Generator 0,
User Output 0,
User Output 1,
Action 1, Action 2,
Line 5 - Optical In 1,
NAND0 Out, NAND1 Out
Rising Edge, Falling Edge,
Level High, Level Low
Off (fixed)
Off, Timed, Trigger Width
73 to 7999685 (µs)
73 to 7999685 (µs)
Off, Continuous
Acquisition Trigger,
Frame Start,
Frame End,
FVAL Start,
FVAL End,
Exposure Start,
Exposure End,
Line2(Opt Out1) Rising Edge,
Line3(Opt Out2) Rising Edge,
Line5(Opt In1) Rising Edge,
Line2(Opt Out1) Falling Edge,
Line3(Opt Out2) Falling Edge,
Line5(Opt In1) Falling Edge
Off, On
GO-2401M-PGE: Analog All
GO-2401C-PGE: Analog All,
Digital Red,
Digital Blue
Analog All: 1 to 16
Digital Red & Blue:
0.447 to 5.624 (color
only)
— 46 —
GO-2401M-PGE / GO-2401C-PGE
Default value
Configure image acquisition settings.
Continuous
Select the image acquisition mode.
Start image acquisition.
Stop image acquisition.
153
In [Multi Frame] mode, set the number of
frames to acquire.
32.8423
Set the frame rate as a frequency. (unit: Hz)
30448
Set the frame rate as a time. (unit: µs)
Frame Start
Select the trigger operation.
Off
Select the trigger mode.
Execute a software trigger.
Line 5 - Optical
Select the trigger signal source.
In 1
Rising Edge
Select the polarity of the trigger signal
(rising edge of
(i.e., location of signal at which trigger is
input signal)
applied).
Off
Select the trigger overlap operation.
Timed (control
Select the exposure mode.
via exposure
time)
30172 (µs)
Set the exposure time. The maximum
value varies depending on the
[Acquisition Frame Rate Raw] value.
30172 (µs)
Set the raw exposure time.
Off
Set whether to enable auto exposure.
Configure event control settings.
Select the event for which to send
notifications.
Off
Select whether to output event messages.
Configure analog control settings.
Analog All
Select the gain to configure.
(master gain)
Master gain: 1
Set the gain value.
R, B: 1
Description

Advertisement

Table of Contents
loading

This manual is also suitable for:

Go-2401c-pge

Table of Contents