v Follow the suggested actions in the order in which they are listed in the Action column until the problem is
solved.
v See Chapter 7, "Parts listing for IBM Flex System p260 and p460 Compute Nodes," on page 97 to determine
which components are CRUs and which components are FRUs.
v If an action step is preceded by Trained service technician only, that step must be performed only by a trained
service technician.
Isolation
procedure or
symbolic failing
item
Symptom
FSPSP04
A problem has been
detected in the
service processor
firmware.
FSPSP05
The service processor
has detected a
problem in the
platform firmware.
The service processor
FSPSP06
reported a suspected
intermittent problem.
FSPSP07
The time of day has
been reset to the
default value.
Action
1. Perform a firmware update. See "Updating the firmware" on page 22.
2. If the problem persists, replace the system-board and chassis assembly,
as described in "Replacing the system-board and chassis assembly" on
page 83.
1. Perform a firmware update. See "Updating the firmware" on page 22.
2. If the problem persists, replace the system-board and chassis assembly,
as described in "Replacing the system-board and chassis assembly" on
page 83.
Contact your next level of support.
1. Use the chdate command to set the Virtual I/O Server date and time
by using one of the following syntax statements:
chdate [-year YYyy]
[-month mm]
[-day dd]
[-hour HH]
[-minute MM]
[-timezone TZ]
chdate mmddHHMM[YYyy|yy]
[-timezone TZ]
2. If the problem persists, replace the battery, as described in "Removing
the battery" on page 64 and "Installing the battery" on page 65.
Chapter 8. Troubleshooting
471