PCI expansion card (PIOCARD) problem isolation procedure

The hardware that controls PCI adapters and PCI card slots detected an error. The direct select address
(DSA) portion of the system reference code (SRC) identifies the location code of the failing component.
The following table shows the syntax of a nine-word B700xxxx system reference code (SRC) as it might
be displayed in the event log of the IBM Chassis Management Module (CMM). Additional information
for the event can be viewed by clicking more... in the message field.
The first word of the SRC in this example is the message identifier B7001111. This example numbers each
word after the first word to show relative word positions. The seventh word is the direct select address,
which is 77777777 in the example.
Table 18. Nine-word SRC in the CMM event log
Severity
Source
Date
Jan 21, 2012
Critical
Blade_05
07:15 AM
Depending on your operating system and the utilities installed, error messages might also be stored in an
operating system log. For more information, see the documentation that comes with the operating
system.
The Table 19 on page 463 shows the procedure for isolating which PCI expansion card is failing.
462
Power Systems: IBM Flex System p260 and p460 Compute Nodes Installation and Service Guide
Message
Additional information for event
Node
Firmware. Replace UNKNOWN (5008FECF B7001111
SN#xxxxxxxxxxxx
22222222 33333333 44444444 55555555 66666666 77777777
message: (System
88888888 99999999)
event) system
hardware failure.