IBM Flex System p260 Installation And Service Manual page 162

Hide thumbs Also See for Flex System p260:
Table of Contents

Advertisement

B2001321 • B2002250
B2001321
Explanation: A problem occurred during the startup of a partition.
Response: Verify that the correct slot is specified for the load source. Then restart the partition.
B2001322
Explanation: In the partition startup, code failed during a check of the load source path.
Response: Verify that the path for the load source is specified correctly. Then restart the partition.
B2002048
Explanation: A problem occurred during a partition Main Storage Dump. A mainstore dump startup did not
complete due to a copy error.
Response: Go to Isolating firmware problems.
B2002054
Explanation: A problem occurred during a partition Main Storage Dump. A mainstore dump IPL did not complete
due to a configuration mismatch.
Response: Go to Isolating firmware problems.
B2002058
Explanation: A problem occurred during a partition Main Storage Dump. A mainstore dump startup did not
complete due to a copy error.
Response: Go to Isolating firmware problems.
B2002210
Explanation: Informational system log entry only.
Response: No corrective action is required.
B2002220
Explanation: Informational system log entry only.
Response: No corrective action is required.
B2002250
Explanation: During the startup of a partition, an attempt to toggle the power state of a slot has failed.
Response: Check for server firmware updates; then, install the updates if available.
150
Power Systems: IBM Flex System p260 and p460 Compute Nodes Installation and Service Guide