2D14-9021 • 2D14-9027
2D14-9021
Explanation: Two or more disks are missing from a RAID-5 or RAID 6 Disk Array. Use MAP3111 to determine
resolution.
Response:
2D14-9022
Explanation: Two or more disks are missing from a RAID-5 or RAID 6 Disk Array. Use MAP3111 to determine
resolution.
Response:
2D14-9023
Explanation: One or more Disk Array members are not at required physical locations. Use MAP3112 to determine
resolution.
Response:
2D14-9024
Explanation: Physical location of Disk Array members conflict with another Disk Array. Use MAP3190 to determine
resolution.
Response:
2D14-9025
Explanation: Incompatible disk installed at degraded disk location in Disk Array. Use MAP3110 to determine
resolution.
Response:
2D14-9026
Explanation: Previously degraded disk in Disk Array not found at required physical location. Use MAP3190 to
determine resolution.
Response:
2D14-9027
Explanation: Disk Array is or would become degraded and parity data is out of synchronization. Use MAP3113 to
determine resolution.
Response: