Table 21. IBM Flex System p260 Compute Node and IBM Flex System p460 Compute Node LEDs (continued)
Callout
3
DRV1 LED (HDD or SSD)
4
Drive board LED (solid-state drive interposer, which is integrated in the cover)
5
Management card LED
6
System board LED
7
Light path power LED
8
DIMM LEDs
9
ETE connector LED

Light path diagnostics LEDs

Use the descriptions of the LEDs to diagnose the problem and to take corrective action.
Table 22 describes the LEDs on the system board and the suggested actions for correcting any detected
problems.
Table 22. Light path diagnostic LED information for the IBM Flex System p260 Compute Node
v Follow the suggested actions in the order in which they are listed in the Action column until the problem is
solved.
v See Chapter 7, "Parts listing for IBM Flex System p260 and p460 Compute Nodes," on page 97 to determine
which components are CRUs and which components are FRUs.
v If an action step is preceded by Trained service technician only, that step must be performed only by a trained
service technician.
Light path
diagnostics LED is
lit
Description
None
An error occurred and cannot be isolated, or
the service processor failed.
Battery error
A battery error occurred.
P1-E1
DIMM x error
A memory error occurred.
P1-C1 DIMM 1
P1-C2 DIMM 2
P1-C3 DIMM 3
P1-C4 DIMM 4
P1-C5 DIMM 5
P1-C6 DIMM 6
P1-C7 DIMM 7
P1-C8 DIMM 8
P1-C9 DIMM 9
P1-C10 DIMM 10
P1-C11 DIMM 11
P1-C12 DIMM 12
P1-C13 DIMM 13
P1-C14 DIMM 14
P1-C15 DIMM 15
P1-C16 DIMM 16
488
Power Systems: IBM Flex System p260 and p460 Compute Nodes Installation and Service Guide
Unit LEDs
Action
An error occurred that is not represented by a
light path diagnostics LED. Check the event
log for information about the error.
Replace the battery, as described in "Removing
the battery" on page 64 and "Installing the
battery" on page 65.
1. Verify that the DIMM indicated by the lit
LED is a supported memory module, as
described on the ServerProven website.
2. Replace the DIMM indicated by the lit
LED, as described in "Removing a DIMM"
on page 55 and "Installing a DIMM" on
page 58.
Note: Multiple DIMM LEDs do not
necessarily indicate multiple DIMM failures. If
more than one DIMM LED is lit, replace one
DIMM at a time until the error goes away.