B7005120 • B7005191
B7005120
Explanation: System firmware detected an error
Response: If the system is not exhibiting problematic behavior, you can ignore this error. Otherwise, go to Isolating
firmware problems.
B7005121
Explanation: System firmware detected a programming problem for which a platform dump may have been
initiated.
Response:
1. Collect the event log information.
2. Collect the platform dump information.
3. Go to Isolating firmware problems.
B7005122
Explanation: An error occurred during a search for the load source.
Response: If the partition fails to startup, go to Isolating firmware problems. Otherwise, no corrective action is
required.
B7005123
Explanation: Informational system log entry only.
Response: No corrective action is required.
B7005190
Explanation: Operating system error. The server firmware detected a problem in an operating system.
Response: Check for error codes in the partition that is reporting the error and take the appropriate actions for
those error codes.
B7005191
Explanation: System firmware detected a virtual I/O configuration error.
Response:
1. Use the management console to verify or reconfigure the invalid virtual I/O configuration.
2. Check for server firmware updates; then, install the updates if available.
176
Power Systems: IBM Flex System p260 and p460 Compute Nodes Installation and Service Guide