IBM Flex System p260 Installation And Service Manual page 182

Hide thumbs Also See for Flex System p260:
Table of Contents

Advertisement

B7000106 • B7000302
B7000106
Explanation: System firmware failure.
Response:
1. Collect the event log information.
2. Collect the platform dump information.
3. Go to Isolating firmware problems.
B7000107
Explanation: System firmware failure. The system detected an unrecoverable machine check condition.
Response:
1. Collect the event log information.
2. Collect the platform dump information.
3. Go to Isolating firmware problems.
B7000200
Explanation: System firmware has experienced a low storage condition
Response: No immediate action is necessary.
Continue running the system normally. At the earliest convenient time or service window, work with IBM Support to
collect a platform dump and restart the system; then, go to Isolating firmware problems.
B7000201
Explanation: System firmware detected an error.
Response: No immediate action is necessary.
Continue running the system normally. At the earliest convenient time or service window, work with IBM Support to
collect a platform dump and restart the system; then, go to Isolating firmware problems.
B7000202
Explanation: Informational system log entry only.
Response: No corrective action is required.
B7000302
Explanation: System firmware failure
Response:
1. Collect the platform dump information.
2. Go to Isolating firmware problems.
170
Power Systems: IBM Flex System p260 and p460 Compute Nodes Installation and Service Guide

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Flex system p460

Table of Contents