IBM Flex System p260 Installation And Service Manual page 160

Hide thumbs Also See for Flex System p260:
Table of Contents

Advertisement

B2001144 • B2001230
B2001144
Explanation: A problem occurred during the migration of a partition.
The migration of a partition did not complete.
Response: Check for server firmware updates; then, install the updates if available.
B2001148
Explanation: A problem occurred during the migration of a partition.
The migration of a partition did not complete.
Response: Check for server firmware updates; then, install the updates if available.
B2001150
Explanation: During the startup of a partition, a partitioning configuration problem occurred.
Response: Go to Verifying the partition configuration.
B2001151
Explanation: A problem occurred during the migration of a partition.
The migration of a partition did not complete.
Response: Check for server firmware updates; then, install the updates if available.
B2001170
Explanation: During the startup of a partition, a failure occurred due to a validation error.
Response: Go to Verifying the partition configuration.
B2001225
Explanation: A problem occurred during the startup of a partition.
The partition attempted to start up prior to the platform fully initializing. Restart the partition after the platform has
fully completed and the platform is not in standby mode.
Response: Restart the partition.
B2001230
Explanation: During the startup of a partition, a partitioning configuration problem occurred; the partition is lacking
the necessary resources to start up.
Response: Go to Verifying the partition configuration.