Canon mf6600 Series Service Manual page 220

Table of Contents

Advertisement

ADF feed test (ADF FEED TEST)
ADF operation verification mode. Press numeric keypad key 4 on the FUNCTION TEST
menu to select the ADF feed test. Place a document on the document platen and press
the start key to transfer the document at the speed matched to the scan resolution setting.
In this test, enter a transfer speed between 500 and 2000 (mm/s) from the numeric keypad
and verify the transfer speed. Select between the ON and OFF states with the left and
right cursor keys to select between single-sided document feed (OFF) and double-sided
document feed (ON).
Book feed test (6-5: BOOK FEED TEST)
Performs a book feed operation with a specified magnification and in a specified size.
Speaker test (6-6: SPEAKER)
Speaker operation verification mode. Press numeric keypad key 6 on the FUNCTION
TEST menu to select the speaker test. In this test, the speaker generates tonal signals at
100 Hz intervals, from 200 Hz to 5 kHz, in varying sound volumes. Signal output from the
speaker is thus verified.
6-6: SPEAKER
FREQ [1]
VOL [2]
Press numeric
keypad key 1.
SPEAKER
SPEAKER
FREQ TEST
VOL[*] :MIN [#]:MAX
Press the star t key
Signal tone volume adjustment.
to change the
* denotes the minimum, #, the maximum.
transmission frequenc y
The volume is adjustable level by level
using the star t key.
Operation panel test (6-7: OPERATION PANEL)
Operation panel operation verification mode. Press numeric keypad key 7 on the
FUNCTION TEST menu to select the OPERATION PANEL test menu. Functions that can
be verified from this menu are listed below.
- LCD test
Start the OPERATION PANEL test by pressing the start key. The LCD test is carried out
first, displaying all-H characters. Press the start key once again to produce a total black
display.
- LED lamp test
Press the start key after the LCD test to select the LCD lamp test, turning on all lamps on
the operation panel.
8
Service Mode > Test Mode (Test) > Faculty Test > Function Test <(6) FUNCTION TEST>
Press numeric
keypad key 2.
F-8-13
F-8-13
8
Service Mode > Test Mode (Test) > Faculty Test > Function Test <(6) FUNCTION TEST>
- Operation key test
Press the start key after the LCD lamp test to select operation key test (1). The test
succeeds if the characters appearing in the LCD are erased when the corresponding keys
are pressed.
When the entire character display is erased, operation key test (2) launches (only on
models with the FAX feature installed). As in (1), the test succeeds if the characters
appearing in the LCD are erased when the corresponding keys are pressed.
Operation key test (1) correspondence diagram
Character
Operation key
0-9,*,#
Numeric key
A
Enlarge/ Reduce key
B
2-Sided key
OK key
C
D
- key
+ key
E
Image Quality key
F
G
Energy Saver key
H
Copy key
I
SCAN key
J
Density key
Operation key test (2) correspondence diagram
Character
Operation key
0
SEND/FAX key
3
Recall/Pause key
4
Address Book key
8-33
Character
Operation key
K
Collate/2 on 1 key
L
Job Cancel/Status Monitor key
View Settings key
M
N
Paper Select key
O
Menu key
P
Clear key
Q
Report key
R
Stop/Reset key
Log In/Out key
S
T
Paper Settings key
T-8-51
T-8-51
Character
Operation key
5
Coded key
Hook key
8
A - R
One-touch key
T-8-52
T-8-52
8-33

Advertisement

Table of Contents
loading

This manual is also suitable for:

D1100 series

Table of Contents