Detailed Discussions Of Bit 1 - Canon mf6600 Series Service Manual

Table of Contents

Advertisement

SSSW-SW05
List of Functions
Bit
Function
0
not used
1
Conversion from mm to inch
(text mode)
2
Conversion from mm to inch
(text/photo mode)
3
not used
4
not used
5
not used
6
not used
7
not used

Detailed Discussions of Bit 1

Use it to enable/disable millimeter/inch conversion in sub scanning direction for images
read in text mode.
Scanning direction in conversion follows the Bit 2 setting of SW14.
Detailed Discussions of Bit 2
Use it to enable/disable millimeter/inch conversion in sub scanning direction for images
read in text/photo mode while bit 1 is set to '1'.
Scanning direction in conversion follows the Bit 2 setting of SW14.
SSSW-SW12
List of Functions
Bit
Function
0
Time-out period for one page upon
transmission
1
Time-out period for one page upon
transmission
2
not used
3
not used
4
Time-out period for one page upon
reception
5
Time-out period for one page upon
reception
6
not used
8
Service Mode > Service Soft Switch Settings (SSSW) > SSSW-SW12 > List of Functions
1
0
-
-
convert
do not convert
convert
do not convert
-
-
-
-
-
-
-
-
-
-
T-8-20
T-8-20
1
0
1
0
1
0
-
-
-
-
1
0
1
0
-
-
8
Service Mode > Service Soft Switch Settings (SSSW) > SSSW-SW12 > List of Functions
Bit
Function
7
Respective page timer settings for
transmission and for reception
The machine will stop the ongoing communication if the transmission/reception of a single
original page takes 32 min or more. To use the timer for a purpose other than this function,
refer to the tables that follow, and select an appropriate time length.
When 'do not enable' is selected using bit 7, the time-out length for a single page for all
modes will depend on the setting of bit 0 and bit 1.
Time-Out Length for
Bit7 Bit6 Bit5 Bit4 Bit3 Bit2 Bit1 Bit0
Transmission/Reception
*
8 min
0
*
16 min
0
*
32 min
0
*
64 min
0
Time-Out Length for Transmission
Bit7 Bit6 Bit5 Bit4 Bit3 Bit2 Bit1 Bit0
(in text mode)
8 min
1
16 min
1
32 min
1
64 min
1
Time-Out Length for
Bit7
Bit6 Bit5
Reception
*
8 min
1
*
16 min
1
*
32 min
1
*
64 min
1
1
0
enable
do not enable
T-8-21
T-8-21
*
*
*
*
0
0
*
*
*
*
0
1
*
*
*
*
1
0
*
*
*
*
1
1
T-8-22
T-8-22
*
*
*
*
*
0
0
*
*
*
*
*
0
1
*
*
*
*
*
1
0
*
*
*
*
*
1
1
Bit4 Bit3 Bit2 Bit1 Bit0
*
*
*
*
0
0
*
*
*
*
0
1
*
*
*
*
1
0
*
*
*
*
1
1
T-8-23
T-8-23
8-9
8-9

Advertisement

Table of Contents
loading

This manual is also suitable for:

D1100 series

Table of Contents