Canon mf6600 Series Service Manual page 191

Table of Contents

Advertisement

#MENU
No.
Initial setting
Range of setting
01: - 04:
05:
0
ON/OFF
06:
0: DIAL
0
1: SERVICEMAN [1]
2: SERVICEMAN [2]
3: OFF
07:
10
0-15
08:
0: 3429
0
1: 3200
2: 3000
3: 2800
4: 2743
5: 2400
09:
0: 33.6kbs
0
1: 31.2kbs
2: 28.8kbs
3: 26.4kbs
4: 24.0kbs
5: 21.6kbs
6: 19.2kbs
7: 16.8kbs
8: 14.4kbs
9: 12.0kbs
10: 9.6kbs
11: 7.2kbs
12: 4.8kbs
13: 2.4kbs
10:
0: 50Hz
1
1: 25Hz
2: 17Hz
3: 20Hz
11: - 20:
8
Service Mode > Default Settings > Service Mode Menus
Function
not used
NL equalizer setting
line monitor setting
transmission level setting
V.34 baud rate
V.34 transmission speed
pseudo CI signal frequency setting
not used
T-8-2
T-8-2
8
Service Mode > Default Settings > Service Mode Menus
#NUMERIC
No.
Initial setting
Range of
setting
001:
002:
10 (10%)
(1-99)
003:
15 (15lines)
(2-99)
004:
12 (12times)
(1-99)
005:
4 (4sec)
(1-60)
006:
4 (4sec)
(1-60)
007: - 009:
010:
5500 (55sec)
(0-9999)
011:
3500 (35sec)
(0-9999)
012:
013:
1300 (13sec)
(500-3000)
014:
015:
120 (1200ms)
(0-999)
016:
4 (4sec)
(0-9)
017:
100 (1000ms)
(0-999)
018:
0 (0ms)
(0-999)
019:
200 (2000ms)
(0-999)
020:
100 (1000ms)
(0-999)
021:
0 (0ms)
(0-999)
022:
200 (2000ms)
(0-999)
023:
4
(0-7)
024:
20 (-20dBm)
(0-20)
025:
60 (60sec)
(0-999)
026:
027:
0
(0-20)
028: - 055:
056:
101
(0-999)
057:
201
(0-999)
058:
0
(0-999)
059:
0
(0-999)
060:
0
(0-999)
061:
0
(0-999)
062: - 080:
Function
not used
RTN signal transmission condition (1) setting
RTN signal transmission condition (2) setting
RTN signal transmission condition (3) setting
NCC pause time (pre-ID code) setting
NCC pause time (post-ID code) setting
not used
line connection identification time length
T.30 T1 timer (for reception)
not used
T30 EOL timer
not used
hooking detection time setting
fax/tel switch-over function: between line acquisition
and pseudo RBTtransmission
pseudo RBT signal pattern: ON time setting
pseudo RBT signal pattern: OFF time (short) setting
pseudo RBT signal pattern: OFF time (long) setting
pseudo CI signal pattern: ON time setting
pseudo CI signal pattern: OFF time (short) setting
pseudo CI signal pattern: OFF time (long) setting
fax/tel switch-over pseudo RBT transmission level
fax/tel switch-over pseudo RBT transmission level
Answering machine connection function signal
detection time
not used
V21 low-speed flag preamble detection time length
not used
count type select 1
count type select 2
count type select 3
count type select 4
count type select 5
count type select 6
not used
8-4
T-8-3
T-8-3
8-4