Tr-069 Settings - Yeastar Technology TA400 User Manual

Hide thumbs Also See for TA400:
Table of Contents

Advertisement

metric. Routing metrics are assigned to routes by routing
protocols to provide measurable statistic which can be used to
judge how useful (how low cost) a route is.
Interface
Define which internet port to go through.

TR-069 Settings

TR-069 (Technical Report 069) is a Broadband Forum (formerly known as DSL Forum)
technical specification entitled CPE WAN Management Protocol (CWMP). It defines
an application layer protocol for remote management of end-user devices. As a
bidirectional SOAP/HTTP-based protocol, it provides the communication between
customer-premises equipment (CPE) and Auto Configuration Servers (ACS).
Yeastar TA400/800 acts as a CPE, enable TR-069 and configure the parameters in
the corresponding fields, if configured correctly, the gateway will establish the TR-069
session with the ACS.
Items
Description
URL of the TR-069 ACS. This is the URL the Yeastar CPEs will
ACS URL
send TR-069 messages to.
Username for HTTP authentication against the ACS. Leave it
ACS Username
blank if no ASC username.
Password for HTTP authentication against the ACS. Leave it
ACS Password
blank if no ASC password.
Set the Yeastar device to start a new session after ―Periodic
Enable
Periodic
Inform Interval‖.
Inform
Time in seconds where the CPE will initiate a new session
Periodic
Inform
against the ACS.
Interval(s)
Enable this option to discover the CPE's public IP address if it is
Enable STUN
located behind a NAT.
STUN
Server
The STUN Server address and port.
Address/Port
Figure 9-9 TR-069 Settings
Table 9-5 Description of TR-069 Settings