Installation Precautions - HP ProCurve Switch 1600M Installation Manual

Table of Contents

Advertisement

Installation Precautions:

Follow these precautions when installing your HP Switch 1600M.
W a r n i n g
C a u t i o n s
The rack or cabinet should be adequately secured to prevent it from
becoming unstable and/or falling over.
Devices installed in a rack or cabinet should be mounted as low as
possible, with the heaviest device at the bottom and progressively lighter
devices installed above.
Make sure that the power source circuits are properly grounded, then use
the power cord supplied with the switch to connect it to the power source.
If your installation requires a different power cord than the one supplied
with the switch, be sure to use a power cord displaying the mark of the
safety agency that defines the regulations for power cords in your country.
The mark is your assurance that the power cord can be used safely with
the switch.
Ensure that the switch does not overload the power circuits, wiring, and
over-current protection. To determine the possibility of overloading the
supply circuits, add together the ampere ratings of all devices installed on
the same circuit as the switch and compare the total with the rating limit
for the circuit. The maximum ampere ratings are usually printed on the
devices near the AC power connectors.
Do not install the switch in an environment where the operating ambient
temperature might exceed 55°C (131°F).
Make sure the air flow around the sides and back of the switch is not
restricted.
Make sure that if no module is installed in the module slot, the cover plate
is installed to cover the slot. A cover plate is required for safe operation,
and to ensure proper switch cooling.
Installing the Switch 1600M
Installation Summary
2-3