SPEC
Item
IGNITION CONTROL SYSTEM
Oil pressure switch
Power bobbin (Y/B – Y/B)
loaded
@ cranking 1*
@1,500 r/min
@3,500 r/min
open circuit
@ cranking 2*
@1,500 r/min
@3,500 r/min
Electrothermal valve coil
resistance
Engine temperature sensor
resistance
@ 5 ˚C (41 ˚F)
@ 20 ˚C (68 ˚F)
@ 70 ˚C (158 ˚F)
Engine speed limiter
Retard timing
Ignition off
Reset
Overheat speed control
STARTING SYSTEM
Fuse
STARTER MOTOR
Type
Rating
Output
Brush length limit
Commutator undercut
CHARGING SYSTEM
Lighting coil output peak voltage
loaded
@ cranking 1*
@1,500 r/min
@3,500 r/min
open circuit
@ cranking 2*
@1,500 r/min
@3,500 r/min
* Cranking 1: Open circuit
Cranking 2: Related parts are connected.
MAINTENANCE SPECIFICATIONS
kPa (kg/cm
(Y/B – Y/B)
(Y – Y)
Unit
Moray 25 M
2
, psi)
V
V
V
V
V
V
kΩ
kΩ
kΩ
r/min
r/min
r/min
r/min
A
Second
kW
mm (in)
mm (in)
V
V
V
V
V
V
2-7
Model
Moray 25 E
15.5 (0.16, 2.25)
7
30
80
10
40
80
6.7 ~ 7.1
2.5
1.25
0.176
6,200 ± 80
6,300 ± 80
6,000 ± 80
2,000 ~ 3,000
20
Bendix
30
1.1
6.4 (0.25)
0.8 (0.03)
10
25
65
10
25
60