Download Print this page

Upper Case Assy; Exploded Diagram; Removal And Installation Chart - SELVA MARINE Moray 25 Service Manual

Advertisement

BRKT

UPPER CASE ASSY.

EXPLODED DIAGRAM

, E

REMOVAL AND INSTALLATION CHART

Step
Procedure/Part name
UPPER CASE ASSY. REMOVAL
Lower unit
Bottom cowling
1
Lower mount housing
2
Lower rubber damper (side)
3
Lower rubber damper (front)
4
Ground lead
5
Upper damper
6
Upper damper retaining plate
7
Upper case assy.
UPPER CASE ASSY.
Q'ty
Follow the left "Step" for removal.
Refer to "LOWER UNIT" in chapter 6.
Refer to "BOTTOM COWLING".
2
2
1
NOTE:
1
Remove the lead at three different points.
1
1
1
Reverse the removal steps for installation.
7-7
Service points