wsm Kubota L4100 Workshop Manual page 325

Table of Contents

Advertisement

L4100, WSM
Main Switch Key at OFF Position
1. Turn the main switch off.
2. Measure the resistance with an ohmmeter across the B terminal
and the AC terminal, B terminal and ST terminal, and B terminal
and G terminal.
3. If infinity is not indicated, the contacts of the main switch are
faulty.
B terminal –
AC terminal
B terminal –
Resistance
ST terminal
B terminal –
G terminal
Main Switch Key at ON Position
1. Turn the main switch on.
2. Measure the resistance with an ohmmeter across the B terminal
and the AC terminal.
3. If 0 ohm is not indicated, the B – AC contacts of the main switch
are faulty.
B terminal –
Resistance
AC terminal
Main Switch Key at START Position
1. Turn and hold the main switch key at the START position.
2. Measure the resistances with an ohmmeter across the B
terminal and the G terminal, and across the B terminal and the
AC terminal, and across the B terminal and the ST terminal.
3. If 0 ohm is not indicated, these contacts of the main switch are
faulty.
B terminal –
G terminal
B terminal –
Resistance
ST terminal
B terminal –
AC terminal
Main Switch Key at PREHEAT Position
1. Turn and hold the main switch key at the PREHEAT position.
2. Measure the resistance with an ohmmeter across the B terminal
and the G terminal, and across the B terminal and the AC
terminal.
3. If 0 ohm is not indicated, these contacts of the main switch are
faulty.
B terminal –
G terminal
Resistance
B terminal –
AC terminal
9-S8
ELECTRICAL SYSTEM
Infinity
Infinity
Infinity
9Y1210278ELS0026US0
0 Ω
9Y1210278ELS0027US0
0 Ω
0 Ω
0 Ω
9Y1210278ELS0028US0
0 Ω
0 Ω
9Y1210278ELS0029US0
(EU)