Wiring, Pipes and Rods
1. Disconnect 1P connector (1) to coolant temperature sensor.
2. Disconnect glow plug terminal (9).
3. Disconnect accelerator cable (7), 2P connector to engine stop
solenoid (8) and then set aside the wiring harness.
4. Disconnect power steering delivery hose (5), power steering
return hose (2).
5. Disconnect pump inlet hose (6), I-PTO delivery pipe (4) and 3P
delivery pipe (3).
(When reassembling)
Independent PTO delivery
pipe joint bolt
Tightening torque
Power steering delivery
hose joint bolt
(1) 1P Connector
(Coolant Temperature Sensor)
(2) Power Steering Return Hose
(3) 3P Delivery Pipe
(4) I-PTO Delivery Pipe
(5) Power Steering Delivery Hose
3-S12
TRANSMISSION
35 to 39 N·m
3.5 to 4.0 kgf·m
26 to 28 lbf·ft
49 to 58 N·m
5.0 to 6.0 kgf·m
37 to 43 lbf·ft
(6) Pump Inlet Hose
(7) Accelerator Cable
(8) 2P Connector
(Engine Stop Solenoid)
(9) Glow Plug Terminal