Installing The Top Interposer Module - Dell PowerEdge FX2 Owner's Manual

Hide thumbs Also See for PowerEdge FX2:
Table of Contents

Advertisement

Removing a storage sled
Removing a power supply unit
Removing the CMC module
Removing an I/O module
Removing a PCIe module
Removing the system cover
Removing a cooling fan
Removing the cooling-fan cage
Removing the bottom interposer module

Installing the top interposer module

Prerequisites
CAUTION: Many repairs may only be done by a certified service technician. You should only
perform troubleshooting and simple repairs as authorized in your product documentation, or as
directed by the online or telephone service and support team. Damage due to servicing that is
not authorized by Dell is not covered by your warranty. Read and follow the safety instructions
that came with the product.
NOTE: This is a field replaceable unit (FRU). Removal and installation procedures must be performed
only by Dell certified service technicians.
1.
Ensure that you read the
2.
Follow the procedure listed in
3.
Remove the top interposer module.
NOTE: You must remove the top interposer module to replace a faulty module, install half-
width or full-width sleds, or service other components inside the system.
Steps
1.
Slide the top interposer module into the upper bay of the system until the pins on the interposer
module engage with the connectors on the midplane.
2.
Install the two screws to secure the top interposer module to the top of the system.
3.
Slide the top partition into the system.
4.
Install the three screws to secure the top partition to the top of the system.
5.
Turn the system over with the bottom side of the system facing up.
6.
Install the two screws to secure the top interposer module to the middle plate.
7.
Install the three screws to secure the top partition to the middle plate.
8.
Turn the system over with the top side of the system facing up.
Next steps
1.
Install the following:
bottom interposer module
cooling-fan cage
cooling fans
system cover
PCIe modules, if applicable
I/O module(s)
CMC module
Safety
instructions.
Before working inside your
system.
73