Removing The Top Interposer Module - Dell PowerEdge FX2 Owner's Manual

Hide thumbs Also See for PowerEdge FX2:
Table of Contents

Advertisement

2.
Follow the procedure listed in
Related Tasks
Installing the cooling-fan cage
Installing a cooling fan
Installing the system cover
Installing a PCIe module
Installing an I/O module
Installing the CMC module
Installing a power supply unit
Installing a storage sled
Installing a compute sled

Removing the top interposer module

Prerequisites
CAUTION: Many repairs may only be done by a certified service technician. You should only
perform troubleshooting and simple repairs as authorized in your product documentation, or as
directed by the online or telephone service and support team. Damage due to servicing that is
not authorized by Dell is not covered by your warranty. Read and follow the safety instructions
that came with the product.
NOTE: This is a field replaceable unit (FRU). Removal and installation procedures must be performed
only by Dell certified service technicians.
NOTE: You must remove the top interposer module to replace a faulty module, install half-width or
full-width sleds, or service other components inside the system.
NOTE: You must remove the bottom interposer module before removing the top interposer
module.
1.
Ensure that you read the
2.
Follow the procedure listed in
3.
Remove the following:
sleds
power supplies
CMC module
I/O module(s)
PCIe modules, if applicable
system cover
cooling fans
cooling-fan cage
bottom interposer module
Steps
1.
Turn the system over with the bottom side of the system facing up.
2.
From the bottom of the system:
a. Remove the three screws that secure the top partition to the middle plate.
70
After working inside your
Safety
instructions.
Before working inside your
system.
system.

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Poweredge fx2sE24s

Table of Contents