Precautions In Servicing; Electrical Parts - Suzuki RM-z450 Owner's Service Manual

Hide thumbs Also See for RM-z450:
Table of Contents

Advertisement

12-3
FI SYSTEM DIAGNOSIS

PRECAUTIONS IN SERVICING

When handling the component parts or servicing the FI system,
observe the following points for the safety of the system.

ELECTRICAL PARTS

CONNECTOR/COUPLER
• When connecting a connector, be sure to push it in until a
click is felt.
• With a lock type coupler, be sure to release the lock when dis-
connecting, and push in fully to engage the lock when con-
necting.
• When disconnecting the coupler, be sure to hold the coupler
body and do not pull the lead wires.
• Inspect each terminal on the connector/coupler for looseness
or bending.
• Push in the coupler straightly. An angled or skewed insertion
may cause the terminal to be deformed, possibly resulting in
poor electrical contact.
• Inspect each terminal for corrosion and contamination.
The terminals must be clean and free of any foreign material
which could impede proper terminal contact.
• Before refitting the sealed coupler, make sure its seal rubber
is positioned properly. The seal rubber may possibly come off
the position during disconnecting work and if the coupler is
refitted with the seal rubber improperly positioned, it may
result in poor water sealing.
• Inspect each lead wire circuit for poor connection by shaking it
by hand lightly. If any abnormal condition is found, repair or
replace.
Click

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents