Post Error Codes - IBM xSeries 342 2RX Maintenance Manual

Hardware maintenance manual
Table of Contents

Advertisement

AC Good LED
DC Good LED
On
Off
On
On

POST error codes

In the following error codes, X can be any number or letter.
Error Code/Symptom
062 (Three consecutive boot failures using
the default configuration.)
101, 102 (System and processor error)
106 (System and processor error)
111 (Channel check error)
114 (Adapter read-only memory error)
129 (Internal cache error)
151 (Real time clock error)
161 (Real time clock battery error)
Description
Standby mode or dc
problem.
Power is OK.
FRU/Action
1. Run Configuration/Setup
2. Battery
3. System Board
4. Processor
1. System Board
1. System Board
1. Failing 15A adapter
2. Memory Dimm
3. System Board
1. Failing Adapter
2. Run Diagnostsics
1. Processor
2. Optional Processor (if installed)
1. Run Diagnostics
2. Battery
3. System Board
1. Run Configuration/Setup
2. Battery
3. System Board
FRU/Action
1. Check system board cable connectors J32,
J33, and J35. Move jumper on J32's
extension cable to pins 2-3 to bypass power
control. If the DC Good LED comes on,
press Ctrl+Alt+Delete. Watch the screen for
any POST errors. Check the System Error
Log for any listed problems. If the system
powers up with no errors:
a. Power Switch Assembly
b. System Board
2. Remove the adapters and disconnect the
cables and power connectors to all internal
and external devices. Power-on the system.
If the DC Good LED comes on, replace the
adapters and devices one at a time until
you isolate the problem.
3. Power Supply
4. Power Backplane
5. System Board
N/A
Symptom-to-FRU index