Text Messages; Starting The Diagnostic Programs - IBM xSeries 342 2RX Maintenance Manual

Hardware maintenance manual
Table of Contents

Advertisement

fff
ttt
iii
date
cc
text message

Text messages

The diagnostic text message format is as follows:
Function Name: Result (test specific string)
where:
Function Name
Result can be one of the following:
Passed
Failed This result occurs when the diagnostic test discovers an error.
User Aborted
Not Applicable
Aborted
Warning
Test Specific String

Starting the diagnostic programs

You can press F1 while running the diagnostic programs to obtain Help
information. You also can press F1 from within a help screen to obtain online
documentation from which you can select different categories. To exit Help and
return to where you left off, press Esc.
To start the diagnostic programs:
1. Turn on the server and watch the screen.
14
Hardware Maintenance Manual: xSeries 342 Model 1RX, 2RX, 1TG, 2TG
is the three-digit function code that indicates the function being tested
when the error occurred. For example, function code 089 is for the
microprocessor.
is the three-digit failure code that indicates the exact test failure that was
encountered.
is the three-digit device ID.
is the date that the diagnostic test was run and the error recorded.
is the check digit that is used to verify the validity of the information.
is the diagnostic message that indicates the reason for the problem.
is the name of the function being tested when the error occurred. This
corresponds to the function code (fff) given in the previous list.
This result occurs when the diagnostic test completes without any errors.
This result occurs when you stop the diagnostic test before it is complete.
This result occurs when you specify a diagnostic test for a device that is
not present.
This result occurs when the test could not proceed because of the system
configuration.
This result occurs when a possible problem is reported during the
diagnostic test, such as when a device that is to be tested is not installed.
This is additional information that you can use to analyze the problem.
Note: To run the diagnostic programs, you must start the server with the
highest level password that is set. That is, if an administrator password

Advertisement

Table of Contents
loading

This manual is also suitable for:

Xseries 342 2tgXseries 342 1tgXseries 342 1rx

Table of Contents