2. Obtain an SMP-capable operating system (optional). For a list of supported
3. If two microprocessors are installed, the microprocessor installed in connector
Attention: To avoid damage and ensure proper server operation when you install
To install an additional microprocessor:
56
Hardware Maintenance Manual: xSeries 342 Model 1RX, 2RX, 1TG, 2TG
operating systems, see http://www.ibm.com/pc/us/compat/ on the World
Wide Web.
U69 is the startup processor, and the microprocessor installed in U68 is the
application processor.
a new or an additional microprocessor, use microprocessors that have
the same cache size and type, and the same clock speed.
Microprocessor internal and external clock frequencies must be
identical.
1. Review the information in "Before you begin" on page 42.
2. Turn off the server and peripheral devices and disconnect all external cables
and power cords; then remove the cover (see "Removing the cover and bezel"
on page 44).
3. Remove the fan 3 assembly by lifting the orange handle on top of the fan
assembly and pulling the fan assembly away from the server.
4. Remove the air baffle by grasping it at the sides and lifting it from the server.
Fan 3
Air baffle