Diagnostic Panel LED
TEMP LED on (look at test cases)

Diagnostic error codes

Note: In the following error codes, if XXX is 000, 195, or 197 do not replace a
Error Code/Symptom
001-XXX-000 (Failed core tests)
001-XXX-001 (Failed core tests)
001-250-000 (Failed System Board ECC)
001-250-001 (Failed System Board ECC)
005-XXX-000 (Failed Video test)
011-XXX-000 (Failed COM1 Serial Port test) 1. System Board
011-XXX-001 (Failed COM2 Serial Port test) 1. System Board
014-XXX-000 (Failed Parallel Port test)
015-XXX-001 (USB interface not found,
board damaged)
015-XXX-015 (Failed USB external loopback
test)
FRU/Action
1. Ambient temperature must be within normal operating specifications.
See "Features and specifications" on page 3.
2. Ensure fans are operating correctly.
3. Examine System Error Log.
a. System over recommended temperature
b.
1) Information LED Panel
2) System Board
c. DASD over recommended temperature (DASD LED also on)
1) Overheating hard drive
2) DASD Backplane
3) System Board
d. System over recommended temperature for CPU X (where X is CPU 1,
2,) (CPU LED also on)
1) CPU X
e. System Board over recommended temperature
4. If the CPU LED on the diagnostics panel is also on, one of the
microprocessors has caused the error.
FRU. The description for these error codes are:
000
The test passed.
195
The Esc key was pressed to abort the test.
197
This is a warning error and may not indicate a hardware failure.
For all error codes, replace/follow the FRU/Action indicated.
FRU/Action
1. System Board
1. System Board
1. System Board
1. System Board
1. System Board
1. System Board
1. System Board
1. Make sure parrallel port is not disabled.
2. Re-run USB external loopback test.
3. System board
85
Symptom-to-FRU index

Advertisement

Table of Contents
loading

This manual is also suitable for:

Xseries 342 2tgXseries 342 1tgXseries 342 1rx

Table of Contents