Attention: Replace a fan that has failed within 48 hours to help ensure proper
To replace a hot-swap fan assembly:
1. Remove the cover. See "Removing the cover and bezel" on page 44.
2. The LED on the failing fan assembly will be lit. Remove the failing fan
3. Slide the replacement fan assembly into the server until it clicks into place.
4. Verify that the FAN LED on the diagnostics panel on the system board is not
5. Replace the cover. See "Installing the server cover and bezel" below.
Installing the server cover and bezel
To install the server cover:
1. Place the cover-release latch in the open (up) position and align the flanges on
62
Hardware Maintenance Manual: xSeries 342 Model 1RX, 2RX, 1TG, 2TG
cooling.
Attention: To ensure proper system cooling, do not remove the top cover for
more than 30 minutes during this procedure.
assembly from the server by lifting the orange handle on the top of the fan
assembly and and pulling the fan assembly away from the server.
lit. If the FAN LED is lit, reseat the fan.
the left and right sides of the cover with the slots on the server chassis.
Handle
Fan 2
Fan 1
Cover-release latch
Side latch
Fan 3
Side latch
Bezel