HEARTH PLATE / COMPONENT ACCESS DOORS

INSTALL HEARTH PLATE / COMPONENT ACCESS DOORS
1.
Install glass frame assembly.
2.
Install component access doors by rotating bottoms toward center of fireplace far enough to insert mounting studs at top of glass
valance through hole at top of access door. Lower bottom into position.
3.
Install hearth plate, making sure long angled flange sits behind access door handles, securing in place.
REMOVE HEARTH PLATE / COMPONENT ACCESS DOORS
1.
Remove hearth plate from front of fireplace by lifting up and out.
2.
Remove component access doors by rotating bottoms toward center of fireplace until top of doors can be released from mounting stud
at top of glass valance.
DO NOT OPERATE THIS FIREPLACE WITH THE GLASS FRONT REMOVED, CRACKED OR BROKEN.
WARNING
REPLACEMENT OF THE GLASS SHOULD BE DONE BY A LICENSED OR QUALIFIED SERVICE PERSON.
REMOVE GLASS FRAME ASSEMBLY
1.
Remove hearth plate and component access doors.
2.
Using a 7/16" nut driver, remove (3) nuts securing bottom of glass frame assembly.
3.
Lift glass frame assembly up and off (3) tabs at top of firebox.
INSTALL GLASS FRAME ASSEMBLY
1.
Place glass frame assembly top over tabs at top of firebox.
2.
Reinstall (3) nuts to assembly bottom.
3.
Reinstall component access doors and hearth plate.
Component Access Doors
Hearth Plate
Figure 16a

GLASS FRAME

16
Rotate toward center
to remove and install
Nuts securing glass valance bottom